| Category 1 - Machinery space components (175-250 microns) - Low pressure pipes, steam valves, air ejection valves, etc. | |
| Category II - Top-side weather equipments (175-250 microns) - Helicopter decks, stanchions, capstan, lighting fixtures, etc. | |
| Category III - (175-250 microns) - Decks in wet compartments, pump room and fan room decks, AC and machinery foundations, etc. |
Thus, the objective of this study is to propose an alternative coating scheme which provides extended corrosion protection, and is viable, too. With this backdrop, various tests and techniques have been used to assess mechanical strength and corrosion behavior of the coating systems (mentioned below), which could be taken as preliminary pointers towards judging the efficacy of these hybrid paint schemes.
Experimental Work
Salient features of the substrate and coating types used in the study are mentioned below:
| Substrate - Mild steel (Lloyds Grade B) | |
| Surface preparation - SA 2.5 (~75 microns anchor profile) | |
| Metalizing process - Electric arc spray | |
| Sealer coat - Brush/spray painting | |
| Epoxy type - Lapox B11/K541 liquid epoxy system | |
| Polyurethane (PU) type - 2-pack high-build pipcothane (spray) |
The samples under investigation are designated as follows for ease of identification -
Table 1: Sample Identification
| Samples Composition (%) | Type (Unsealed) | Epoxy Sealed | Polyurethane Sealed |
| 99.95 Zn | A (250)* | AE (A+ 75) | AP (A+ 75) |
| 85 Zn/15 Al | B (125) | BE (B+ 75) | BP (B+ 75) |
| 55 Al/45 Zn | C (125) | CE (C+ 75) | CP (C+ 75) |
*(dft) = dry film thickness
In order to evaluate the performance of the sealed metalized coatings with respect to their corrosion behavior and mechanical strength in marine environment, various experimental techniques and accelerated tests have been carried out starting with microstructural inspection.
The characterization of thermal spray coatings in samples A, B and C was done using optical and scanning electron microscopy (SEM) after due metallographic preparation. Energy-dispersive analysis of X-rays (EDAX) for elemental identification and quantification and X-ray diffraction (XRD) for identification of phases in the metal spray coatings were also carried out. Various important properties like, surface porosity content, bond and impact strength of the coating systems were evaluated using standard techniques. A combination of accelerated environmental exposures and electrochemical tests were employed to assess the corrosion behavior of the coating systems.
Results and Discussions
Coating characterization
The inspection of the microstructure helps to detect cracks, coating delamination and other defects like porosity. Figures 1-a,b,c show optical micrographs of cross section of samples A, B and C at 150x magnification. The uniformity of the coating thicknesses, the interface bonding, size and distribution of pores and phases can be seen. The sprayed coatings can be seen to be comprised of splat quenched particles, more so in sample A due to lower melting temperatures of zinc (fig. 1-a). The lamellar structure as seen in fig. 1-c, sample C, shows thin dark lines which are oxide layers. The larger dark areas are pores within the coating [2]. The micro-irregularities of the substrate surface anchors the initial layer of spray particles and also re-distributes the residual stresses at the interface so that the coating is less likely to spall. Mechanical inter- locking is the primarey mechanism for the adherence, but some physical and chemical bonding forces may also come into play [3].
SEM micrograph in fig. 2-a shows sample A (pure zinc) to be more dense than the alloyed ones as seen in figs. 2-b and 2-c. Average surface porosity evaluated from a number of micrographs of each type corroborates the above fact.
Sample A shows least porosity (3.5%), sample B, 5.2% and sample C, 7.2%. However, the occurrence of porosity per se, is not much of a deterrence, in fact, pores allow the organic sealer coat good adhesion.
The EDAX results confirmed 99.48 wt. % Zn in sample A, signifying high purity zinc in the spray. Proportionate elemental distribution was obtained for samples B and C as well, indicating efficient spray procedure. XRD diffractographs indicated presence of Al2O3 in alloyed coatings, more so in sample C with 55% Al, which is expected since air/oxygen is involved as compressed air in the process.
Mechanical Strength
Table 2 gives the average adhesive/cohesive strength of various coating systems in dry and wet conditions. The test was conducted as per ASTM C-633 on a Tensile Testing m/c by applying uniaxial force through properly aligned aluminum dollies. The wet bond strength values were obtained after the samples had been subjected to 1000-hour salt spray test.
Table 2: Bond Strength Values
| S. No. | Samples | Bond Strength (dry) in MPa | Bond Strength (wet) in MPa |
| 1 | A | 5.0 | 2.0* |
| 2 | B | 5.5 | 1.8* |
| 3 | C | 8.4 | 1.8* |
| 4 | AE | 8.6 | 1.4* |
| 5 | BE | 8.2 | 5.0 |
| 6 | CE | 7.8 | 4.6 |
| 7 | AP | 7.5 | 2.2 |
| 8 | BP | 7.8 | 5.0 |
| 9 | CP | 8.0 | 6.6 |
* - adhesive failure
The bond strength values obtained are quite satisfactory, particularly in the sealed panels. Most failures recorded were cohesive which signifies that the adhesion to the substrate is still better. In wet conditions, unsealed samples recorded adhesive failure mainly due to the initial ingress of corrosives through the unfilled pores of the metal spray coating.
The Falling weight Test (BS 3900-E3) [4], was carried out to assess the impact strength of the coatings. The results re-confirmed good cohesive strength of the unsealed coatings, showing no cracking or disbandment near the impacted area. The sealed coatings did show few hair line cracks around the impacted area.
Corrosion Tests - Accelerated/Exposure Tests
Assessment of corrosion behavior of the coating systems was done using environmental exposures, accelerated tests and electrochemical tests. Sealed and unsealed panels were put under continuous immersion in natural sea water in an aerated aquarium tank for 13 weeks. At the end of this period, some whitish corrosion product marks were seen on sample A (pure Zn), and to a lesser extent in sample B, but no corrosion marks were seen. Other samples (sealed) were only covered with slime which could be washed off. Sea water was changed periodically in the tank and its pH was monitored weekly.
Figures 3-a and 3-b depict the condition of sealed samples after 1000-hour exposure to accelerated Salt spray (fog) Tests, done as per ASTM B117 [5]. It is clear that although sealed (AE, AP), the zinc metals activity builds up sizeable amount of corrosion products viz., oxides, hydroxides, carbonates/chlorides, which have significant volume expansion, leading to blistering after prolonged exposure, as seen in sample AP. The epoxy sealed samples performed better than the pipcothane (PU) sealed ones.
The results of 10-cycle (80 hours) exposure to accelerated weathering test in a QUV-B weatherometer are shown in figures 4-a and 4-b.
Although not a corrosion test, it is still an effective indicator of the degradation of coating under the combined effects of ultra-violet (UV) radiation and condensation. Here, the pipcothane (PU) coated sample showed no visible degradation, while there was some discoloration observed on the epoxy coating. NO other deterioration was seen.
Electrochemical Tests
Tabulated in Table 3 are E-corr (vs. SCE) and i-corr values of unsealed test sample A, after 1- hour pre-exposure; sample B and C, after 24-hour pre-exposure in 3.5% NaCl solution. The curves obtained from potentiodynamic polarization are shown in figures 5-a,b,c. Fig. 5a clearly represents the electrochemical dissolution tendency of Zn in sample A, while sample C (fig. 5c) shows certain degree of passivation effected due to 55% Al in the spray coating. Al content in the coating helps in forming a tenacious film of aluminum hydroxide on the surface, thereby increasing the IR drop and reducing the corrosion current, i-corr. Thus, it is clear that the protection accorded by Zn spray is purely sacrificial in nature and its life is directly proportional to the thickness of the coating applied. Increase in Al content in the Zn-based metal spray reduces the electrochemical activity of pure Zn coating, thus increasing the longevity of the coating by combining the effects of passivity and sacrificial cathodic protection.
Table 3: Potentiodynamic polarization results
| Samples | E-corr vs. SCE (V) | I-corr (uA/cm2) |
| A | -1.030 | 25.12 |
| B | -1.180 | 15.84 |
| C | -1.140 | 11.22 |
The A.C impedance spectroscopy is regarded as the most effective technique for an objective assessment of coating performance in a given medium [6]. Unfortunately, the difficulty in exact electric circuit modeling for complex electrochemical phenomena of electrolyte-coating-metal interfaces and certain ambiguity in interpretation of its data there after, having not helped the use of this technique as a popular standard tool for performance evaluation. Nevertheless, an attempt has been made here, using CMS 300 software (Gamry Instruments, Inc., USA) interface, to evaluate the comparative corrosion performance among the various coatings systems under consideration here. The coating systems were tested in 3.5% NaCl solution with graphite counter electrode and saturated calomel (SCE) as the reference electrode. The measurements were done at open circuit potential with an amplitude of 10 mV and a frequency range of 0.2-50,000Hz.
Figures 6, 7, 8 and 9 depict the Nyquist plots for samples B, BE, CE and BP respectively, as on day-01 and day-42. In fig. 6-a, the porous nature of unsealed sample B is evident from the low overall resistance value on X-axis. It is clear from the trend that initially, the pores in the coating allow the electrolyte to penetrate; hence, the dissolution reaction starts and at a low impedance value the curve begins to take a downward turn. However, as the system stabilizes, the corrosion products fill the pores, the impedance value rises and the curve straightens, indicating diffusive, but protective mode. Corrosion processes controlled by diffusion can occur in case of formation of insoluble corrosion products that block the pores in the coating [6]. Similar effect is clear in figs. 7-a and 8-a; also, the higher impedance values (~10 to the 6th power ohms), signifies a good barrier effect by the sealer coat. However, it is difficult to get exact coating resistance value so long the trend stays like this. The coating resistance value will go on reducing as the water uptake in the coating increases (fig. 7-b), until the curve tends towards a semi-circle. Sample BP, in fig. 9, signifies a coating with minor defects. The relatively low value of resistance (~10 to the 4th power ohms) indicates the sealer coat also suffering from some porosity. The high frequency component is probably due to the coating itself; whereas, at lower frequency, the straight line close to 45 degrees is representative of the classical Warburg type diffusion process. It is pertinent, however, to mention that no visible corrosion marks had appeared on any of the samples yet. A more comprehensive evaluation will be done on completion of the test.
Conclusions
Performance of pseudo-alloy thermal spray coating (sample C) is better than pre-alloyed (B) or, purely metallic (A) coatings; and, its sealing further yields a synergistic upgradation in the coating performance, both in terms of corrosion behavior and mechanical strength.
Pipcothane (PU) sealer shows excellent resistance to ultra-violet radiation while, Lapox epoxy shows good overall efficacy, particularly with respect to corrosion protection, as indicated by Salt spray and A.C impedance Tests.
Hybrid coatings are not only effective for critical areas of ships, as mentioned earlier, but also for drydock components and equipments like drydock gates, gratings, drain tunnels, access doors, handrails as well as marker buoys and all such critical carbon steel components, as have been successfully proved in Europe and the USA [7].
Acknowledgment
The authors express their gratitude to Mr. Dhirendra Kumar, Scientist "F", Head of Paint Section, NMRL, Ambamath; and Dr. R. V. Bhave, Sc. ‘F', Head, Paint Lab., Naval Dockyard, Mumbaie and RSIC, IIT Bombay for extending their help and facilities in carrying out certain experiments related to the study. We gratefully acknowledge the contributions of M/s Modi Metallizing, Mumbai, M/s Metallizing Equipment Co. Pvt. Ltd., Jodhpur and VCM Polyurethanes, Mumbai in preparation of the samples.